AquaStar™ BWMS
AquaStar™ BWMS Model/Major Specification
- Typical Design Standards of AquaStar™ BWMS
- TRO Max. 10ppm .
-
Model Treatment
Rated Capacity
(m³/hr)Smart Pipe Unit Electrolyzer Unit Gas Separator Unit Power Consumption (kwh) (Dimension)xQ'ty
L x W x H (mm)(Dimension)xQ'ty
L x W x H (mm)(Dimension)xQ'ty
L x W x H (mm)32PSU 10PSU H-150 200 (1370/430/420)x1 (760/600/480)x4 (1100/500/920)x1 9 11 H-200S 350 (1370/530/470)x1 (760/630/520)x4 (1190/530/1150)x1 15 20 H-200-Ex 350 (1370/530/470)x1
(760/630/520)x4 (1190/530/1150)x1 15 20 H-250 500 (1410/530/520)x1
(760/650/570)x4 (1380/580/1350)x1 21 28 H-300 800 (1410/630/570)x1
(800/670/610)x4 (1570/630/1540)x1 34 45 H-300-Ex 800 (1410/630/570)x1
(800/670/610)x4 (1570/630/1540)x1 34 45 H-350 1,100 (1410/630/620)x1 (800/750/670)x4 (1750/670/1750)x1 52 78 H-350-Ex 1,100 (1410/630/620)x1 (800/750/670)x4 (1750/670/1750)x1 52 78 H-400 1,500 (1410/730/670)x1 (800/900/720)x4 (1980/720/1970)x1 71 104 H-450 2,000 (1450/730/720)x1 (800/900/770)x4 (2170/770/2180)x1 95 138 H-550 2,600 (1490/830/820)x1 (840/1040/870)x4 (2550/870/2620)x1 124 186 H-650 3,000 (1490/930/920)x1 (840/1220/970)x4 (2930/970/3010)x1 143 215 H-650-Ex 3,000 (1490/930/920)x1 (840/1220/970)x4 (2930/970/3010)x1 143 215 H-700 4,000 (1490/1030/970)x1 (840/1410/1020)x4 (3110/1020/3170)x1 191 287 H-750 5,000 (1510/1030/1020)x1 (840/1590/1070)x4 (3300/1080/3340)x1 238 357 - Red Color Models : Ex-Proof Type.
- Ex-Proof type approval for remaining models are now in progress.
- Since 2012 and continuously Proven Technology by Real Operating Every installed AquaStar™ BWMS is operating now in all the oceans of the world!
- Benefits
-
- AquaStar™ BWMS is NOT module type.
Only 1 set of AquaStar™ BWMS is enough up to ballast pump capacity 5,000m³/h.
All models are designed to have various dimension from 200 m³/h to 5,000 m³/h (Ballast pump capacity), respectively.
(Not an arrangement of parallel connection of small capacity units.) - Functional Guarantee
- Keeping Performance Standard TRO 8 - 10ppm
- Anyone Operation
- Simple & Easy Design
- No Worries of Frequent Shift of Crews
- Safe System
- Safe Emission to the Outside of the Ship by H2 Gas Collecting Equipment
- Gas Detectors are installed to ensure the safety of vessel and crew.
- No Filter system
- No Clogging & Zero Risk Off-hire
- No Plugging in Ballasting Line
- AquaStar™ BWMS is NOT module type.
- Flexible Design
-